Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Belo Horizonte; s.n; 2021. 95 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1392062

ABSTRACT

A Osteogênese Imperfeita (OI) é uma doença genética rara, caracterizada por ossos frágeis com fraturas recorrentes. Na maioria dos casos a OI, é causada por mutações nos genes COL1A1 ou COL1A2 os quais codificam o colágeno tipo I. Mutações em novos genes envolvidos na via do metabolismo ósseo têm sido descobertas. A OI está associada a alterações dentárias e craniofaciais, sendo as mais prevalentes a dentinogênese imperfeita e a má oclusão. A literatura tem mostrado que é possível predizer o risco de fratura óssea ao analisarmos índices radiomorfométricos e dimensão fractal (DF) da mandíbula em radiografias panorâmicas. O objetivo desta pesquisa foi verificar se há diferenças no padrão de oclusão, na cortical e no trabeculado ósseo mandibular de indivíduos com OI quando comparados com indivíduos sem OI. Desse modo, a tese conta com a apresentação de dois artigos científicos. O primeiro artigo objetivou analisar dois índices radiomorfométricos, o índice cortical mandibular (ICM) e o índice mentual (IM), e a DF do trabeculado ósseo mandibular de indivíduos com OI e comparar com indivíduos sem OI. Foi realizado um estudo transversal, pareado por idade e sexo, com 20 indivíduos com OI e 40 sem OI. Os dados foram obtidos por meio de radiografias panorâmicas de pacientes com OI e sem OI atendidos na Faculdade de Odontologia da Universidade Federal de Minas Gerais. O estudo foi aprovado pelo Comitê de Ética em Pesquisa da UFMG (protocolo 02470518.3.0000.5149). O teste t pareado (p <0,05) foi usado para comparar os valores de IM e DF. O teste do qui-quadrado (p <0,05) comparou o ICM entre os grupos. A média de idade de ambos os grupos foi 13,10 anos (± 6,57). O valor médio do IM foi de 2.08 (±0.79) no grupo de indivíduos com OI e 2.91 (±0.60) para indivíduos sem OI (p<0,001). O valor médio de DF do grupo OI [0.3248 (±0.7240)] foi inferior ao do grupo sem OI [0.3814 (±0.5587)] no côndilo mandibular (p=0,002). O grau C3 do ICM foi mais frequente entre os indivíduos com OI (p <0,001). Indivíduos com OI apresentaram valores menores nos IM e DF, além de pior morfologia da cortical mandibular. O segundo artigo, uma revisão sistemática e meta-análise (já publicada), objetivou avaliar se indivíduos com OI são mais afetados por má oclusão do que indivíduos normotípicos. Foi realizada uma busca nas principais bases. A avaliação do risco de viés e a análise da força de evidência foram conduzidas. Em comparação com indivíduos sem OI, o grupo com OI teve 19,69 vezes mais chance de apresentar má oclusão de Classe III de Angle (OR = 19,69, IC: 9,00­43,09) e apresentar maior mordida cruzada anterior (MD = 6,08, CI: 2,40­9,77). Indivíduos sem OI tiveram um ângulo ANB (MD= 3,88, IC: 1,15­6,61) e ângulo SNA (MD = 2,11, IC: 0,24­3,98) significativamente maiores em comparação com indivíduos com OI. Nenhuma diferença entre os grupos foi encontrada para SNB (MD = −0,50, IC: −2,21 a 1,21) e mordida aberta (MD = 0,98, IC: −0,29 a 2,25). A maioria dos estudos incluídos teve qualidade metodológica moderada. A força da evidência foi baixa ou muito baixa. A ocorrência de má oclusão Classe III de Angle e mordida cruzada anterior foi maior entre os indivíduos com OI em comparação com aqueles sem OI.


Osteogenesis Imperfecta (OI) is a rare genetic disease characterized by fragile bones with recurrent fractures. In most cases, OI is caused by mutations in the COL1A1 or COL1A2 genes which encode type I collagen. Mutations in new genes involved in the bone metabolism pathway have been discovered. OI is associated with dental and craniofacial alterations, the most prevalent being dentinogenesis imperfecta and malocclusion. The literature has shown that it is possible to predict the risk of bone fracture when analyzing radiomorphometric indices and fractal dimension (FD) of the mandible in panoramic radiographs. The objective of this research was to verify if there are differences in the occlusion pattern, in the cortical and in the mandibular bone trabeculate of individuals with OI when compared to individuals without OI. Thus, the thesis has the presentation of two scientific articles. The first article aimed to analyze two radiomorphometric indices, the mandibular cortical index (MCI) and the mentual index (MI), and the FD of the mandibular bone trabeculate of individuals with OI and compare with individuals without OI. A cross-sectional study, matched by age and sex, was carried out with 20 individuals with OI and 40 without OI. Data were obtained through panoramic radiographs of patients with OI and without OI treated at the Faculty of Dentistry of the Federal University of Minas Gerais. The study was approved by the Research Ethics Committee at UFMG (protocol 02470518.3.0000.5149). Paired t-test (p < 0.05) was used to compare MI and DF values. The chi-square test (p < 0.05) compared the ICM between groups. The mean age of both groups was 13.10 years (± 6.57). The mean value of MI was 2.08 (±0.79) in the group of individuals with OI and 2.91 (±0.60) for individuals without OI (p<0.001). The mean FD value of the OI group [0.3248 (±0.7240)] was lower than that of the group without OI [0.3814 (±0.5587)] in the mandibular condyle (p=0.002). ICM grade C3 was more frequent among individuals with OI (p<0.001). Individuals with OI had lower MI and DF values, in addition to worse mandibular cortical morphology. The second article, a systematic review and meta-analysis (already published), aimed to assess whether individuals with OI are more affected by malocclusion than normotypic individuals. A search was carried out in the main bases. Risk of bias assessment and strength of evidence analysis were conducted. Compared with individuals without OI, the group with OI was 19.69 times more likely to have Angle Class III malocclusion (OR = 19.69, CI: 9.00­ 43.09) and to have greater anterior crossbite (MD = 6.08, CI: 2.40­9.77). Subjects without OI had a significantly greater ANB angle (MD= 3.88, CI: 1.15­6.61) and SNA angle (MD= 2.11, CI: 0.24­3.98) compared to subjects with hi. No difference between groups was found for SNB (MD = −0.50, CI: −2.21 to 1.21) and open bite (MD = 0.98, CI: −0.29 to 2.25). Most of the included studies were of moderate methodological quality. The strength of the evidence was low or very low. The occurrence of Angle Class III malocclusion and anterior crossbite was higher among individuals with OI compared to those without OI.


Subject(s)
Osteogenesis Imperfecta , Radiography, Panoramic , Cancellous Bone , Cortical Bone , Malocclusion
2.
Belo Horizonte; s.n; 2021. 128 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1344193

ABSTRACT

Os inibidores de aromatase (IAs) são medicamentos mais comumente utilizados para tratamento para pacientes com câncer de mama. Os IAs atuam inibindo a enzima aromatase, que é responsável pela conversão de hormônios esteroidais. Vários estudos mostram a importância do estrógeno para a formação óssea. Acredita-se que a privação do estrógeno possa ter um efeito deletério no osso causando o aumento da reabsorção óssea, diminuição da densidade mineral óssea (DMO) e com isso o aumento do risco de osteoporose e fraturas. A osteoporose é uma doença sistêmica multifatorial caracterizada pela redução da massa óssea e desorganização estrutural do tecido ósseo. O diagnóstico da osteoporose é baseado em critérios densitométricos da Organização Mundial de Saúde (OMS) com referência na classificação do T-score, realizada pela técnica de absorciometria de energia dupla de raios X (DXA), cujo valor avalia a DMO. Por se tratar de uma doença sistêmica, a osteoporose também afeta os ossos maxilares. Desta forma, o trabalho tem como objetivo avaliar parâmetros imaginológicos em pacientes mulheres que fazem tratamento com; IAs e encaminhadas para investigação de perda de massa óssea em um hospital de referência no tratamento dessas pacientes. Foram avaliadas 40 mulheres sob terapia com IAs. Foram avaliados índices radiomorfométricos (IR) de tomografia computadorizada de feixe cônico (TCFC) e análise fractal (AF) para algumas regiões de interesse (RI), espessura da cortical mandibular (ECM) e índice cortical mandibular (ICM) em radiografias panorâmicas digitais (RPD). Todas as pacientes foram submetidas ao exame DXA para avaliar a condição de DMO e divididas nos grupos: normal e baixa DMO. Para cada IR e para as RI da dimensão fractal, foram estabelecidas a curva característica de operação do receptor (ROC), a área sob a curva (AUC), a sensibilidade e a especificidade com seus receptivos intervalos de confiança. Os valores de AUC para os índices de RPD variaram de 52,6%-75,8%. O índice com a maior AUC foi a ECM, apresentando sensibilidade de 38,1%-100,0% e especificidade de 36,8%-84,2%. Para a AF, a RI do trabeculado total teve a maior sensibilidade, enquanto a RI anterior ao forame mentual teve a maior especificidade. Na análise da TCFC, os valores de AUC variaram de 51,8%-62,0%. Os índices com a AUC mais elevada foram o índice molar (M), com sensibilidade 18,1%-61,6% e especificidade de 66,9%-98,7% e o índice anterior (A) com sensibidade de 25,7%- 70,2% e especificidade de 48,8%-90,9%. O índice da sínfise (S) apresentou a maior sensibilidade e o índice posterior (P) apreentou a maior especificidade. Os índices de tomografia computadorizada inferior (ITC I) apresentou sensibilidade e especificidade razoáveis. Assim a ECM, a AF das RI do ângulo da mandíbula e do trabeculado total da RPD, bem como os índices ITC (I), M, P e A na TCFC mostraram-se úteis para identificar mulheres na pós-menopausa que usavam AI com baixa DMO.


Aromatase inhibitors (AIs) are the most commonly used drugs to treat breast cancer patients. AIs work by inhibiting the aromatase enzyme, which is responsible for converting steroid hormones. Several studies show the importance of estrogen for bone formation. It is believed that estrogen deprivation can have a deleterious effect on bone, causing increased bone resorption, decreased bone mineral density (BMD) and thus an increased risk of osteoporosis and fractures. Osteoporosis is a multifactorial systemic disease characterized by reduced bone mass and structural disorganization of bone tissue. The diagnosis of osteoporosis is based on densitometric criteria of the World Health Organization (WHO) with reference to the T- score classification, performed by the dual energy X-ray absorptiometry (DXA) technique, whose value assesses the BMD. As it is a systemic disease, osteoporosis also affects the maxillary bones. Thus, the study aims to evaluate imaging parameters in female patients undergoing treatment with AIs and referred for investigation of bone mass loss in a reference hospital in the treatment of these patients. Forty women undergoing therapy with AIs were evaluated. Radiomorphometric indices (RI) of cone beam computed tomography (CBCT) and fractal dimension (FD) were evaluated for some regions of interest (ROI), mandibular cortical width (MCW) and mandibular cortical index (MCI) in digital panoramic radiographs (DPR). All patients underwent the DXA exam to assess the status of BMD and divided into groups: normal and low BMD. The AUC values for the DPR indices ranged from 52.6%-75.8%. The index with the highest AUC was the mandibular cortical width ([MCW]; sensitivity: 38.1%-100.0%; specificity: 36.8%-84.2%). For FD, the total trabecular index had the greatest sensitivity, while the index anterior to the mental foramen (MF) had the highest specificity. In CBCT analysis, the values of AUC ranged from 51.8%-62.0%. The indices with the highest AUC were the molar index (M, sensitivity: 18.1%-61.6% and specificity: 66.9%-98.7%) and anterior (A, sensitivity: 25.7%-70.2% and specificity 48.8%-90.9%). The symphysis (S) index had the highest sensitivity, and the posterior (P) index presented the highest specificity. Sensitivity and specificity reasonable were obtained to computed tomography index (Inferior) [CTI (I)]. The MCW, FD of ROI of the mandible angle and total mandibular in the DPR, as well as the CTI (I), M, P, and A indices in the CBCT are useful to identify postmenopausal women who were using AI with low BMD.


Subject(s)
Osteogenesis , Osteoporosis , Bone Density , Aromatase Inhibitors , Estrogens , Radiography, Panoramic , Cone-Beam Computed Tomography , Cancellous Bone , Cortical Bone
3.
Belo Horizonte; s.n; 2019. 154 p. ilus, tab.
Thesis in English, Portuguese | LILACS, BBO | ID: biblio-1049734

ABSTRACT

As lesões fibro-ósseas (LFOs) caracterizam-se pela substituição do osso normal por tecido conjuntivo fibroso e material mineralizado. Displasia fibrosa, fibroma ossificante e displasia cemento-óssea (DCO) compõem este grupo, que além da semelhança histopatológica, pode sobrepor características radiográficas. A correlação de dados clínicos, radiográficos e histopatológicos é necessária para o diagnóstico definitivo. Este trabalho teve como objetivo descrever e avaliar exames odontológicos de imagem de indivíduos diagnosticados com LFOs. Foram desenvolvidos três estudos com metodologias independentes. O primeiro estudo avaliou os efeitos da displasia cemento-óssea em estruturas anatômicas adjacentes por meio de tomografia computadorizada de feixe cônico (TCFC). Foram avaliados 60 casos de DCO, com 244 áreas de lesão envolvendo 426 dentes. A maioria das lesões apresentou aproximadamente 10 mm de diâmetro. Afilamento (n=80) expansão (n=62) e perfuração (n=60) foram os efeitos comuns na cortical óssea. A lâmina dura e o espaço do ligamento periodontal foram descontínuos em todos os dentes. No segundo estudo, 50 radiografias panorâmicas de mulheres com diagnóstico de DCO foram pareadas por idade com 50 radiografias panorâmicas de mulheres sem DCO. Os grupos DCO e não-DCO foram comparados através do índice de espessura da cortical mandibular (ECM), a dimensão fractal (DF) da região de osso trabecular e cortical e o índice cortical mandibular (ICM). O índice de ECM do grupo DCO foi de 3,12 mm (2,15-4,55) e do grupo não-DCO foi 3,52 mm (1,90- 4,70) com diferença estatística entre os grupos (p=0,034). A DF do trabeculado ósseo alveolar normal foi semelhante nos dois grupos, enquanto que menores médias de DF no osso cortical foram encontradas no grupo DCO (p=0,046). A classificação C3 do ICM foi mais comum no grupo DCO (p=0,009). O terceiro foi um estudo preliminar que avaliou a DF em imagens bidimensionais e tridimensionais de TCFC de seis casos de displasia fibrosa e seis de fibroma ossificante. Cortes de reconstrução panorâmica, axial, coronal e sagital foram selecionados em quatro espessuras: 0,25; 5; 15 e 25 mm, e avaliados em 3 formatos de regiões de interesse (RI). Duas metodologias compararam quatro formatos de volumes do interior das lesões. A média de DF das imagens bidimensionais de reconstrução panorâmica e axiais, com 0,25 mm de espessura mostrou diferença significativa entre displasia fibrosa e fibroma ossificante (p<0.05), independente do formato da RI (p>0,05). A média da DF de imagens tridimensionais foi diferente entre os grupos de lesões para a maioria das comparações (p<0.05), independente da metodologia usada. Informações detalhadas sobre a lesão e o envolvimento de estruturas adjacentes podem ser visualizadas em TCFC. Métodos não invasivos como os índices radiomorfométricos e análise fractal podem ser úteis na detecção de baixa densidade mineral óssea, ou mesmo como possível ferramenta de estudo da complexidade de imagens de LFOs.


Fibro-osseous lesions (FOLs) are characterized by the replacement of normal bone with fibrous connective tissue and mineralized material. The group includes the fibrous dysplasia, ossifying fibroma and cemento-osseous dysplasia (COD). These three lesions show similar histopathological and radiographic features. Clinical, radiographic and histopathological data correlation is necessary for the definitive diagnosis. This study aimed to describe and to evaluate dental imaging exams of individuals diagnosed with FOLs. Three studies with independent methodologies were developed. The first study evaluated the effects of COD on the adjacent anatomical structures by means of cone beam computed tomography (CBCT). Sixty cases of COD were evaluated. The assessment of the 60 cases involved 244 lesion areas and 426 teeth. Most lesions presented nearly 10 millimeters (mm) of diameter. Thinning (n=80), expansion (n=62) and perforation (n=60) were common effects on the cortical bone. All 426 teeth presented discontinuation of the lamina dura and of the periodontal ligament space. In the second study, 50 panoramic radiographies of women diagnosed with COD were matched with 50 panoramic radiographies of women without COD according to the individuals' age. Comparisons between groups regarding the mandibular cortical width index (MCW), the fractal dimension (FD) of the region of the trabecular and the cortical bone and the mandibular cortical index (MCI) were carried out. The MCW of the COD group was 3.12 mm (2.15-4.55) and the MCW of the non-COD group was 3.52 mm (1.90-4.70). A significant difference between groups was observed (p=0.034). FD of the normal trabecular alveolar bone was similar in both groups. For the cortical bone, a lower mean FD was observed in the COD group (p=0.046). The MCI C3 was more common in the COD group (p=0.009). The third was a preliminary study, in which the FD was evaluated on twodimensional and three-dimensional CBCT images of six cases of fibrous dysplasia and six cases of ossifying fibroma. Panoramic reconstruction, axial, coronal and sagittal slices were selected in four thicknesses (0.25, 5, 15 and 25 mm) and evaluated in three shapes of regions of interest (ROI). Two methodologies compared four volume formats from inside the lesions. A significant difference between fibrous dysplasia and ossifying fibroma was observed for the mean FD of the twodimensional images of panoramic reconstruction and axial slices with a thickness of 0.25 mm (p<0.05), regardless of the ROI shape (p>0.05). The mean DF of threedimensional images was different between lesion groups for most comparisons (p <0.05), regardless of the methodology used. Detailed information on lesions and involvement of adjacent structures can be viewed in CBCT. Non-invasive methods, such as radiomorphometric indices and fractal analysis may be useful in the detection of low bone mineral density or as a helpful tool for the differentiation of distinct types of FOLs.


Subject(s)
Radiography, Panoramic , Cementoma , Fibroma, Ossifying , Cone-Beam Computed Tomography , Fibrous Dysplasia of Bone , Cancellous Bone , Cortical Bone , Image Processing, Computer-Assisted , Retrospective Studies
4.
Bauru; s.n; 2015. 123 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-773794

ABSTRACT

Os bisfosfonatos são medicamentos amplamente e efetivamente utilizados para o tratamento de doenças osteolíticas. Entretanto, na cavidade oral, é de particular relevância, pois possuem como efeito adverso a osteonecrose dos maxilares induzida pelo uso de bisfosfonatos. Sua etiopatogenia ainda não é bem estabelecida, os métodos de detecção são insatisfatórios e as terapias recomendadas são por vezes, medidas paliativas e ineficazes. Pouco ainda é sabido sobre o efeito do Ácido Zoledrônico na microestrutura óssea, portanto, propusemo-nos a realizar um estudo em modelo animal que analisasse o trabeculado ósseo da mandíbula através da Micro-CT. Foram utilizados 24 ratos machos (Rattus novergicus, albinus, Wistar), com 12 semanas de vida, divididos em 2 grupos: grupo controle (cloreto de sódio 0,9%) e grupo ácido zoledrônico (ácido zoledrônico 0,6mg/kg). As substâncias foram administradas via intraperitoneal a cada 28 dias em um total de 5 doses. Após 150 dias do início do experimento, foi realizada a eutanásia dos animais e então as amostras foram preparadas e escaneadas (Skyscan 1174) para análise da microestrutura óssea através da Micro- CT. O teste t-student demonstrou diferença estatisticamente significativa (p<0,05) em todos os fatores: volume ósseo, densidade óssea, fator de padrão trabecular, índice de modelo estrutural, espessura trabecular, separação trabecular, porosidade total exceção de número de trabéculas e volume tecidual, demonstrando que há alterações significativas na estrutura trabecular pelo uso de bisfosfonatos. O grupo medicado com ácido zoledrônico comparado ao grupo controle demonstrou trabéculas mais espessas, menos separadas e com menores ligações...


Bisphosphonates are widely and effectively drugs used for the treatment of osteolytic disorders. However, in the oral cavity, this situation is of particular relevance as it can lead to bisphosphonate related osteonecrosis of the jaws. Its etiopathogenesis is still not established, detection methods are unsatisfactory and recommended therapies are sometimes palliative and often ineffective. Little is known about the effect of zoledronic acid on the quality of trabecular bone, therefore, we proposed to conduct a study in an animal model to examine the trabecular bone of the jaw through the Micro-CT. 24 male rats were used (Rattus norvegicus, Albinus, Wistar), with 12 weeks old, divided into 2 groups: control group (sodium chloride 0.9%) and group with zoledronic acid (zoledronic acid 0.6 mg / kg). The substances were administered intraperitoneally every 28 days for a total of 5 doses. After 150 days from the beginning of the experiment, the animals were sacrificed and then the samples were prepared and scanned (Skyscan 1174) for analysis of the bone microstructure through Micro-CT. The "t-student" test demonstrated statistically significant differences (p<0.05) in all factors: bone volume, osseous density, trabecular pattern, structure model index, trabecular thickness, trabecular separation, total porosity except trabecular number and tissue volume, demonstrating that there are significant changes in the trabecular structure of the bisphosphonates. Zoledronic Acid compared to control group shows thicker, less separate and lower connected trabeculae...


Subject(s)
Animals , Male , Rats , Bisphosphonate-Associated Osteonecrosis of the Jaw , Bone Density Conservation Agents/adverse effects , Diphosphonates/adverse effects , Imidazoles/adverse effects , Mandible , Bisphosphonate-Associated Osteonecrosis of the Jaw , Bone Density , Mandible/pathology , Rats, Wistar , Tomography, X-Ray Computed
5.
Rev. bras. eng. biomed ; 28(2): 116-123, jun. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-649099

ABSTRACT

A osteoporose é uma doença que causa perda de massa óssea e deterioração da estrutura trabecular. A rede formada pelo osso trabecular é muito importante para estabelecer a competência mecânica do esqueleto. Estudos mostram que a microarquitetura trabecular pode elevar a predição do risco de fratura para cerca de 90 por cento , por isso a sua investigação é de grande interesse da comunidade científica. Vários parâmetros estão relacionados à competência mecânica da estrutura óssea, entretanto, a tortuosidade trabecular ainda não foi seriamente levada em consideração e sua contribuição é desconhecida. Neste trabalho, o enfoque está direcionado à estimativa da tortuosidade trabecular e sua correlação com a conectividade, através da característica de Euler-Poincaré, para amostras do osso rádio distal in  vitro, a partir de imagens de microtomografia computadorizada. Um método para estimar a tortuosidade do volume trabecular é apresentado e a tortuosidade é computada para os dois sentidos das três direções do volume. Os resultados apresentam valores distintos da tortuosidade dependendo da qualidade da rede trabecular e uma correlação positiva (r  =   0,64) com a característica de Euler-Poincaré; além disso, observa-se que a tortuosidade busca alinhar-se nas direções de maiores tensões e compressões imprimidas à rede trabecular. Tais resultados evidenciam a importância da tortuosidade como parâmetro estrutural da rede trabecular.


Osteoporosis is disease causing bone mass loss and deterioration of the trabecular structure. The trabecular network is very important to establish the mechanical competence of the skeleton. It is known that the trabecular microarchitecture can improve the fracture risk prediction up to 90 percent , for this reason the trabecular bone investigation has become of great interest for the scientific community. Several parameters provide structural details of the bone mechanical competence, however, the trabecular network tortuosity has not been seriously taken into account yet and its contribution is unknown. This paper directs attention to the trabecular tortuosity estimation and its correlation to the connectivity, through Euler-Poincaré characteristic, from in  vitro distal radius bone samples by micro-computed tomographic images. A method to estimate the trabecular bone tortuosity is presented and its value is computed for both directions of the three volume axis. The results indicate that the trabecular tortuosity depends on the trabecular network quality and a positive correlation (r  = 0.64) with the Euler-Poincaré characteristic. Inasmuch, it has been observed that the tortuosity tends to get aligned in the direction of main stress imposed on trabecular bone network. These results support the tortuosity as an important structural parameter.


Subject(s)
Humans , Male , Female , Bone Density/physiology , Bone and Bones/physiopathology , Osteoporosis/diagnosis , Primary Prevention/trends
6.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-599159

ABSTRACT

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não indicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Polyurethanes/chemistry , Analysis of Variance , Chromium Alloys/chemistry , Prosthesis Fitting
7.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-865625

ABSTRACT

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Polyurethanes/chemistry , Analysis of Variance , Chromium Alloys/chemistry , Prosthesis Fitting
SELECTION OF CITATIONS
SEARCH DETAIL